ATP Network 500 Test Report


Tests Performed :

The results shown below are valid ONLY at the

Time of the Test.

Intermittent problems may not have been detected !

Current Consumption

Ignition Output

Injector Outputs

Internal Voltages

Stepper Motor Operation

Neutral Input

Manifold Pressure Input

Water Temperature Input

Throttle Input

Supply Voltage Compensation

Octane Adjust Input

Lambda Input

Rev Limit

Flashcode Operation


Test Results :

Test 1:

The ECU failed the test(s) detailed below :

Test 1:

Test 1:

Stepper Motor :

Throttle Pot Compensation Error

Test 1:

Drift. AVG: +25% Worst: +25%

Test 1:

Stepper Motor :

Engine Revs Compensation Error

Test 1:

Drift. AVG: -28% to +33% Worst: +33%

Test 1:

Stepper Motor :

Neutral Compensation Error

Test 1:

Drift. AVG: -25% Worst: -25%

Test 1:

Ignition Timing :

Manifold Pressure Calibration Error

Test 1:

Drift. AVG: +10% Worst: +48%

Test 1: